T2K US Beamline and ND280 Collaboration Document 100-v1

DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

Bladder fiducial volume uncertainty due to center spine

Document #:
us-b280-doc-100-v1
Document type:
Technical Report
Submitted by:
Jeff Wilkes
Updated by:
Jeff Wilkes
Document Created:
13 Nov 2007, 17:30
Contents Revised:
13 Nov 2007, 17:30
DB Info Revised:
13 Nov 2007, 17:30
Viewable by:
  • Public document
Modifiable by:
Abstract:
Estimates the uncertainty in water volume introduced by using 2 bladders side by side with a center strut (instead of one bladder, full width). Error is < 1%, so within allowable tolerance.
Files in Document:
Authors:
Associated with Events:
held from 08 Sep 2007 to 09 Sep 2007 in SBU Physics D-122
DocDB Home ]  [ Search ] [ Last 20 Days ] [ List Authors ] [ List Topics ] [ List Events ]

DocDB Version 8.5.5, contact Document Database Administrators